Skip to content

PLCamera.CounterEventSourceEnum Class#

Sets which event increases the currently selected counter.

Applies to: CameraLink, GigE, ace 2 CXP, ace 2 GigE, ace 2 USB, ace USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Visibility: Beginner

Selected by: CounterSelector

The feature documentation may provide more information.

Inheritance Hierarchy#

System.Object
  Basler.Pylon.ParameterListEnum
    Basler.Pylon.PLCamera.CounterEventSourceEnum

Constructors#

 NameDescription
Public methodPLCamera.CounterEventSourceEnum Initializes a new instance of the PLCamera.CounterEventSourceEnum class
 

Properties#

 NameDescription
Public propertyAcquisitionActive

The selected counter counts the number of Acquisition Active signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyAcquisitionEnd

Counts the number of Acquisition End.

Applies to: CameraLink and GigE

Public propertyAcquisitionStart

Counts the number of Acquisition Start.

Applies to: CameraLink and GigE

Public propertyAcquisitionTrigger

Counts the number of Acquisition Trigger.

Applies to: CameraLink and GigE

Public propertyAction1

The selected counter counts the number of action commands received for action signal 1.

Applies to: ace 2 GigE

Public propertyAction2

The selected counter counts the number of action commands received for action signal 2.

Applies to: ace 2 GigE

Public propertyCounter1Active

The selected counter counts the number of Counter 1 Active signals. By default, a Counter 1 Active signal is generated whenever counter 1 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyCounter1End

The selected counter counts the number of Counter 1 End signals. A Counter 1 End signal is generated whenever counter 1 is stopped, reset, or when it has reached its maximum value.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, ace USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyCounter1Start

The selected counter counts the number of Counter 1 Start signals. A Counter 1 Start signal is generated whenever counter 1 is started.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyCounter2Active

The selected counter counts the number of Counter 2 Active signals. By default, a Counter 2 Active signal is generated whenever counter 2 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyCounter2End

The selected counter counts the number of Counter 2 End signals. A Counter 2 End signal is generated whenever counter 2 is stopped, reset, or when it has reached its maximum value.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, ace USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyCounter2Start

The selected counter counts the number of Counter 2 Start signals. A Counter 2 Start signal is generated whenever counter 2 is started.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyCounter3End

The selected counter counts the number of counter 3 end events.

Applies to: ace USB

Public propertyCxpTrigger0

The selected counter counts the number of CXP Trigger 0 signals.

Applies to: ace 2 CXP, boost CoaXPress and racer 2 CXP

Public propertyCxpTrigger1

The selected counter counts the number of CXP Trigger 1 signals.

Applies to: ace 2 CXP, boost CoaXPress and racer 2 CXP

Public propertyExposureActive

The selected counter counts the number of Exposure Active signals. By default, an Exposure Active signal is generated whenever exposure is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyExposureEnd

Counts the number of Exposure End.

Applies to: CameraLink and GigE

Public propertyExposureStart

The selected counter counts the number of Exposure Start signals.

Applies to: CameraLink, GigE, ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyExposureTriggerWait

The selected counter counts the number of Exposure Trigger Wait signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyFlashWindow

The selected counter counts the number of Flash Window signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress and dart USB

Public propertyFrameBurstActive

The selected counter counts the number of Frame Burst Active signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyFrameBurstTriggerWait

The selected counter counts the number of Frame Burst Trigger Wait signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyFrameEnd

Counts the number of Frame End.

Applies to: CameraLink and GigE

Public propertyFrameStart

The selected counter counts the number of Frame Start events.

Applies to: CameraLink, GigE and ace USB

Public propertyFrameTrigger

The selected counter counts the number of Frame Trigger events.

Applies to: CameraLink, GigE and ace USB

Public propertyFrameTriggerWait

The selected counter counts the number of Frame Trigger Wait signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyLine1

The selected counter counts the number of Line 1 signals. A Line 1 signal is generated whenever the input or output signal on Line 1 changes as specified by the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyLine2

The selected counter counts the number of Line 2 signals. A Line 2 signal is generated whenever the input or output signal on Line 2 changes as specified by the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyLine3

The selected counter counts the number of Line 3 signals. A Line 3 signal is generated whenever the input or output signal on Line 3 changes as specified by the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyLine4

The selected counter counts the number of Line 4 signals. A Line 4 signal is generated whenever the input or output signal on Line 4 changes as specified by the Counter Event Activation parameter.

Applies to: dart 2 USB and dart USB

Public propertyLineEnd

Counts the number of Line End.

Applies to: CameraLink and GigE

Public propertyLineStart

Counts the number of Line Start.

Applies to: CameraLink and GigE

Public propertyLineTrigger

The selected counter counts the number of Line Trigger events.

Applies to: CameraLink and GigE

Public propertyName The full name of CounterEventSource (Overrides ParameterListEnum.Name.)
Public propertyOff

The selected counter is disabled.

Applies to: CameraLink, GigE, ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyPeriodicSignal1

The selected counter counts the number of Periodic Signal 1 signals.

Applies to: ace 2 GigE

Public propertySoftwareSignal1

The selected counter counts the number of Software Signal 1 signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertySoftwareSignal2

The selected counter counts the number of Software Signal 2 signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertySoftwareSignal3

The selected counter counts the number of Software Signal 3 signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyTimer1Active

The selected counter counts the number of Timer 1 Active signals. By default, a Timer 1 Active signal is generated whenever timer 1 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyTimer1End

The selected counter counts the number of Timer 1 End signals. A Timer 1 End signal is generated whenever timer 1 has elapsed.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyTimer2Active

The selected counter counts the number of Timer 2 Active signals. By default, a Timer 2 Active signal is generated whenever timer 2 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

Public propertyTimer2End

The selected counter counts the number of Timer 2 End signals. A Timer 2 End signal is generated whenever timer 2 has elapsed.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

 

Methods#

 NameDescription
Public methodToString The full name of CounterEventSource (Overrides Object.ToString()()()().)
 

PLCamera.CounterEventSourceEnum.ToString Method#

The full name of CounterEventSource

Return Value#

Type: String
Returns the full name of CounterEventSource

PLCamera.CounterEventSourceEnum Constructor#

Initializes a new instance of the PLCamera.CounterEventSourceEnum class

PLCamera.CounterEventSourceEnum.AcquisitionActive Property#

The selected counter counts the number of Acquisition Active signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.AcquisitionEnd Property#

Counts the number of Acquisition End.

Applies to: CameraLink and GigE

PLCamera.CounterEventSourceEnum.AcquisitionStart Property#

Counts the number of Acquisition Start.

Applies to: CameraLink and GigE

PLCamera.CounterEventSourceEnum.AcquisitionTrigger Property#

Counts the number of Acquisition Trigger.

Applies to: CameraLink and GigE

PLCamera.CounterEventSourceEnum.Action1 Property#

The selected counter counts the number of action commands received for action signal 1.

Applies to: ace 2 GigE

PLCamera.CounterEventSourceEnum.Action2 Property#

The selected counter counts the number of action commands received for action signal 2.

Applies to: ace 2 GigE

PLCamera.CounterEventSourceEnum.Counter1Active Property#

The selected counter counts the number of Counter 1 Active signals. By default, a Counter 1 Active signal is generated whenever counter 1 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Counter1End Property#

The selected counter counts the number of Counter 1 End signals. A Counter 1 End signal is generated whenever counter 1 is stopped, reset, or when it has reached its maximum value.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, ace USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Counter1Start Property#

The selected counter counts the number of Counter 1 Start signals. A Counter 1 Start signal is generated whenever counter 1 is started.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Counter2Active Property#

The selected counter counts the number of Counter 2 Active signals. By default, a Counter 2 Active signal is generated whenever counter 2 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Counter2End Property#

The selected counter counts the number of Counter 2 End signals. A Counter 2 End signal is generated whenever counter 2 is stopped, reset, or when it has reached its maximum value.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, ace USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Counter2Start Property#

The selected counter counts the number of Counter 2 Start signals. A Counter 2 Start signal is generated whenever counter 2 is started.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Counter3End Property#

The selected counter counts the number of counter 3 end events.

Applies to: ace USB

PLCamera.CounterEventSourceEnum.CxpTrigger0 Property#

The selected counter counts the number of CXP Trigger 0 signals.

Applies to: ace 2 CXP, boost CoaXPress and racer 2 CXP

PLCamera.CounterEventSourceEnum.CxpTrigger1 Property#

The selected counter counts the number of CXP Trigger 1 signals.

Applies to: ace 2 CXP, boost CoaXPress and racer 2 CXP

PLCamera.CounterEventSourceEnum.ExposureActive Property#

The selected counter counts the number of Exposure Active signals. By default, an Exposure Active signal is generated whenever exposure is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.ExposureEnd Property#

Counts the number of Exposure End.

Applies to: CameraLink and GigE

PLCamera.CounterEventSourceEnum.ExposureStart Property#

The selected counter counts the number of Exposure Start signals.

Applies to: CameraLink, GigE, ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.ExposureTriggerWait Property#

The selected counter counts the number of Exposure Trigger Wait signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.FlashWindow Property#

The selected counter counts the number of Flash Window signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress and dart USB

PLCamera.CounterEventSourceEnum.FrameBurstActive Property#

The selected counter counts the number of Frame Burst Active signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.FrameBurstTriggerWait Property#

The selected counter counts the number of Frame Burst Trigger Wait signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.FrameEnd Property#

Counts the number of Frame End.

Applies to: CameraLink and GigE

PLCamera.CounterEventSourceEnum.FrameStart Property#

The selected counter counts the number of Frame Start events.

Applies to: CameraLink, GigE and ace USB

PLCamera.CounterEventSourceEnum.FrameTrigger Property#

The selected counter counts the number of Frame Trigger events.

Applies to: CameraLink, GigE and ace USB

PLCamera.CounterEventSourceEnum.FrameTriggerWait Property#

The selected counter counts the number of Frame Trigger Wait signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Line1 Property#

The selected counter counts the number of Line 1 signals. A Line 1 signal is generated whenever the input or output signal on Line 1 changes as specified by the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Line2 Property#

The selected counter counts the number of Line 2 signals. A Line 2 signal is generated whenever the input or output signal on Line 2 changes as specified by the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Line3 Property#

The selected counter counts the number of Line 3 signals. A Line 3 signal is generated whenever the input or output signal on Line 3 changes as specified by the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Line4 Property#

The selected counter counts the number of Line 4 signals. A Line 4 signal is generated whenever the input or output signal on Line 4 changes as specified by the Counter Event Activation parameter.

Applies to: dart 2 USB and dart USB

PLCamera.CounterEventSourceEnum.LineEnd Property#

Counts the number of Line End.

Applies to: CameraLink and GigE

PLCamera.CounterEventSourceEnum.LineStart Property#

Counts the number of Line Start.

Applies to: CameraLink and GigE

PLCamera.CounterEventSourceEnum.LineTrigger Property#

The selected counter counts the number of Line Trigger events.

Applies to: CameraLink and GigE

PLCamera.CounterEventSourceEnum.Name Property#

The full name of CounterEventSource

PLCamera.CounterEventSourceEnum.Off Property#

The selected counter is disabled.

Applies to: CameraLink, GigE, ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.PeriodicSignal1 Property#

The selected counter counts the number of Periodic Signal 1 signals.

Applies to: ace 2 GigE

PLCamera.CounterEventSourceEnum.SoftwareSignal1 Property#

The selected counter counts the number of Software Signal 1 signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.SoftwareSignal2 Property#

The selected counter counts the number of Software Signal 2 signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.SoftwareSignal3 Property#

The selected counter counts the number of Software Signal 3 signals.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Timer1Active Property#

The selected counter counts the number of Timer 1 Active signals. By default, a Timer 1 Active signal is generated whenever timer 1 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Timer1End Property#

The selected counter counts the number of Timer 1 End signals. A Timer 1 End signal is generated whenever timer 1 has elapsed.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Timer2Active Property#

The selected counter counts the number of Timer 2 Active signals. By default, a Timer 2 Active signal is generated whenever timer 2 is started. You can change this behavior using the Counter Event Activation parameter.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP

PLCamera.CounterEventSourceEnum.Timer2End Property#

The selected counter counts the number of Timer 2 End signals. A Timer 2 End signal is generated whenever timer 2 has elapsed.

Applies to: ace 2 CXP, ace 2 GigE, ace 2 USB, boost CoaXPress, dart 2 USB, dart USB and racer 2 CXP